hp-ux磁带备份失败故障解决
报错日志:WARNING: The pax command returned a non-zero exit status (exit status 1)* Creation of system archive completeNOTE: The following files are in the list of files that were on thesystem, but they are no longer present. These files are notincluded in the back-up:/var/tmp/ign_configure/make_sys_image.log/var/spool/cron/tmp/croutWLIa01156ERROR: The make_sys_image command failed. The system recovery archive will not be created.======= 12/22/07 22:16:41 EAT make_tape_recovery completed unsucce
HP VA7110 硬盘故障重建失败处理
一、 问题描述用户VA7110 有一硬盘故障,VA自动rebuild失败,11月25更换硬盘后rebuild仍然失败,之后VA做balance一周都未完成,I/O比较慢,数据库checkpoint时间最高达到200多秒,业务严重受到影响二、 告警信息#armdsp -a vaVendor ID:______________________________HPProduct ID:_____________________________A6189BArray World Wide Name:__________________50060b00001535a8Array Serial Number:____________________00SG324J0103Alias:__________________________________vaSoftware Revision:______________________1.09.02 - 019
更换HP小型机系统镜像故障盘
1 1、告警信息fep2#[/]lvdisplay -v /dev/vg00/lvol3--- Logical volumes ---LV Name /dev/vg00/lvol3VG Name /dev/vg00LV Permission read/write LV Status available/stale Mirror copies 1 Consistency Recovery MWC Schedule parallel LV Size (Mbytes) 140 Current LE 35 Allocated PE 70 Stripes 0 Stripe Size (Kbytes) 0 Bad block off Allocation strict/contiguous IO Timeout (Seconds) default --- Distribution of logical volume ---PV Name LE on PV PE on PV /dev/dsk/c1t2d0 35 35 /dev/dsk/c2t2d0 35 35 --- Logical ex
HP MC/ServiceGuard双机配置修改
1、1、 错误描述LVM: Performed a switch for Lun ID = 0 (pv = 0x0000000043802000), from raw device 0x1f050100 (with priority: 0, and current flags: 0x40) to raw device 0x1f070100 (with priority: 1, and current flags: 0x0).LVM: VG 64 0x020000: PVLink 31 0x050100 Failed! The PV is still accessible.LVM: Performed a switch for Lun ID = 0 (pv = 0x000000004380e000), from raw device 0x1f050200 (with priority: 0, and current flags: 0x40) to raw device 0x1f070200 (with priority: 1, and current flags: 0x0).
某电信HP双机主数据网卡切换实施方案
一、 问题描述经检查系统日志和对日志的分析,发现sdp1的syslog.log中有报类拟” Mar 17 13:03:39 scp1 cmcld: HB connection to 192.168.1.5 not responding, closing”的错误,且用lanadmin –g 1查看到SDP1的主数据网卡中有报” Inbound Errors = 19746”的错误,初步怀疑SDP1主数据网卡LAN1到相应Cisco2950交换机端口的整条链路可能存在异常,故建议3月18日晚先把SDP1的主数据网卡从LAN1切换LAN2上面去。二、 实施步骤<一>、在sdp1主数据库用以下命令做完成备份$ontape -s –L 0<二>、关闭sdp2备机数据库,以避免切换主备
Solaris2.6+Sun cluster2.2+Vxvm2.6下的逻辑卷扩卷
硬件环境:N1145+D1000软件环境:solaris2.6+sun cluster2.2+vxvm2.6+informix1、操作准备:1)确认需扩容的磁盘空间目前大小# vxprint -ht lvrbsDisk group: datadgV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODESD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODEv lvrbs fsgen ENABLED ACTIVE 10240000 SELECT - (raid0+1大小为5G)pl lvrbs-01 lvrbs ENABLED ACTIVE 10248840 STRIPE 3/128 RWsd datadg01-03 lvrbs-01 datadg01 4099440 3416200 0/0 c1t9d0 ENAsd
HP-UX rebuild /stand/vmunix内核文件
一、问题描述在scp1主机上执行netstat -in和dmesg命令时,不能正常执行,输出以下结果:SCP1#[/]netstat -in: no namelistSCP1#[/]dmesgSep 20 17:30Can't get kernel namelist二、告警信息SCP1#[/]netstat -in: no namelistSCP1#[/]dmesgSep 20 17:30Can't get kernel namelist三、分析问题原因经远程拔号检查,诊断确认为内核文件不正常,需要重新rebuild一下生成新的/stand/vmunix内核文件,否则主机重启后机器将不能正常启动。四、处理过程SCP1#[/]netstat -inin: no namelistSCP1#[/]dmesgSep 21 16:44Can't get kernel namelistSCP1
Hp VA7100更换控制器方案
一、故障现像VA7100正常关闭后,加电启动时有一控制器状态如下:M/C2 Controller Failed无法使用串口登陆M/C2控制器,控制器的指示灯亮黄灯。二、系统及背景情况由于某用户电信机房UPS使用比较久,工作稳定性存在隐患,在电源割接需要将HP RP2470*2、VA7100*2和两台光纤交换机都割接到新的UPS上,这样就需要主机和存储都下电。三、原因分析控制使用比较久,而且这个控制器一直处于备用状态。由于长时间没有断电,相对比较脆弱,所以在断电和加电后就很容易损坏。四、解决方法查看VA指示器,发现有一控制的contraller灯亮黄灯,使用armdsp
HP APA模式设置导致双网卡丢包
一、 问题描述某用户反馈HP小型机系统访问很慢。二、 告警信息通过拨号登录到您的主机scp3上,检查了相关的日志,包括: syslog,event log,network log,bdf,top,glance,ts99,crash,但是没有发现告警或错误。三、 分析问题原因年前此主机曾多次出现过此现象,经对主机和网络做了全面检查,均没有发现异常,当时重启主机后,故障恢复。本次再次通过拨号登录到您的主机scp3上,检查了相关的日志,包括: syslog,event log,network log,bdf,top,glance,ts99,crash,但是没有发现告警或错误。后来经检查发现网卡配置了APA(双网卡绑定),而APA901
HP小型机CPU IDEL值过低问题处理
一、 问题描述某用户HP主机的CPU IDEL值有时出现过低的现象。二、 告警信息1>top输出fep1#[/usr/contrib/bin/dump]topSystem: stfep1 Thu Apr 17 10:48:02 2008Load averages: 1.15, 1.18, 1.18100 processes: 98 sleeping, 2 runningCpu states:CPU LOAD USER NICE SYS IDLE BLOCK SWAIT INTR SSYS0 1.45 0.0% 0.4% 0.8% 98.8% 0.0% 0.0% 0.0% 0.0%1 0.85 0.4% 0.2% 0.6% 98.8% 0.0% 0.0% 0.0% 0.0%--- ---- ----- ----- ----- ----- ----- ----- ----- -----avg 1.15 0.2% 0.4% 0.6% 98.8% 0.0% 0.0% 0.0% 0.0%Memory: 157092K (7862
HP FC60 RAID级别更改方案
1 背景xx用户智能网SDP业务为数据核心部分,现在以一套RP4440双机加一台VA7110和DS2405存储,为了确保SDP业务的在双机同时出现故障时,能向200用户提供业务,特此做一台个SDP业务应急处理机。2 可行性分析2.1 现有应急环境硬件配置主机:2*N4000存储:FC60(硬盘:8.5G * 24 ),做RAID 5后总容量为:8.5G*23=195.5G(注:据实际值可能会有所偏)双机:A.11.09 MC / Service Guard数据库:Informix 7.31操作系统:HP-UX B.11.00存储现有状态:FC60做RAID 0/1 总容量为:101G 划分了LUN0(16.9G)、LUN1(42.2G)、LUN2(42.2G).2.2 业务主机配置