| Subject: | Repca: Error -Sqlexception On Getting Sid And Systemname Information | |||
| Doc ID: | Note:388445.1 | Type: | PROBLEM | |
| Last Revision Date: | 29-JAN-2007 | Status: | MODERATED | |
In this Document
Symptoms
Cause
Solution
References
| This document is being delivered to you via Oracle Support's Rapid Visibility (RaV) Rapid Visibility (RaV) process, and therefore has not been subject to an independent technical review. |
- MRCA 10.1.2.0.3 fails fails with errors connecting to target database (10.1.2.0.2)
- Errors in repca.log:
SpecifyDBConnectPage] DB User : SYS
[SpecifyDBConnectPage] DB Host(s) : hostname.domain,
[SpecifyDBConnectPage] DB Port(s) : 1526,
[SpecifyDBConnectPage] DB Service Name : PORTALD
[SpecifyDBConnectPage] Is Rac : false
[SpecifyDBConnectPage] DB REMOTE HOST NAME :hostname.domain
[SpecifyDBConnectPage] Is Remote Host :true
ERROR -SQLException on getting SID and SYSTEMNAME information
ERROR - SQLException :Io exception: There is no process to read data written to a pipe.
- Errors in sqlnet.log:
Fatal NI connect error 12170.
VERSION INFORMATION:
TNS for IBM/AIX RISC System/6000: Version 10.2.0.2.0 - Production
TCP/IP NT Proto Adapter for IBM/AIX RISC System/6000: Version 10.2.0.2.0 - Production
Oracle Bequeath NT Proto Adapter for IBM/AIX RISC System/6000: Version 10.2.0.2.0 - Production
Tracing not turned on.
Tns error struct:
ns main err code: 12535
TNS-12535: TNS:operation timed out
ns secondary err code: 12606
nt main err code: 0
nt secondary err code: 0
nt OS err code: 0
To implement the solution, execute the following steps::
1. In $ORACLE_HOME/network/admin/listener.ora, of the database where the Metadata Repoistory is to be loaded, add the line:
INBOUND_CONNECT_TIMEOUT_LISTENER = 0
2. In the Oracle Server 10g sqlnet.ora, add the line:
SQLNET.INBOUND_CONNECT_TIMEOUT = 0
3. Stop and restart the database and the listener for the changes to take effect
4. Rerun RepCA