Applies to:
Oracle Database - Enterprise Edition - Version 10.2.0.3 and later
Information in this document applies to any platform.
***Checked for relevance on 25-Jun-2013***
Symptoms
Reporting errors on import datapump job.
ORA-39125: Worker unexpected fatal error in KUPW$WORKER.PUT_DDLS while calling DBMS_METADATA.CONVERT [TABLE_STATISTICS]
ORA-06502: PL/SQL: numeric or value error
LPX-00225: end-element tag "MLOTHOTFT" does not match start-element tag "FT"
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 105
ORA-06512: at "SYS.KUPW$WORKER", line 6234
Cause
Objects exported were referencing objects outside of the schema.
Solution
To implement the solution, please execute the following steps:
1. Precreate all referenced objects.
来自 “ ITPUB博客 ” ,链接:https://blog.itpub.net/30204651/viewspace-1753238/