Symptoms
Created an XML Publisher report with Excel output. When numeric data includes leading zeros, these are dropped in the output e.g. 00123 becomes 123.
Example source XML:
<root>
<invoices>
<invoice>
<invoice_number>0000123</invoice_number>
</invoice>
<invoice>
</root>
Cause
Excel automatically trims leading and trailing zeros when in what it sees as numeric data.
To keep leading or trailing zeros where the data is not numeric but actually a string,
such as an invoice number, Excel has to see the numbers as a string value not numeric.
Solution
1. In the rtf template, use the “Insert -> Symbol” function to insert a very small
0xA0 (NO-BREAK SPACE) character (font size 1 or 2pt) in front of the number string field.
2. One can also try:
3. Another option:
During XML template design, Instead of the using the tag < ?TAG_NAME ? >
use ="<?TAG_NAME?>". It wraps the value with double quotes. Now Excel treat value as character and doesn't trim the leading zeros of value.
Note: space between < and ? and tag name is not required.
4. Retest for the issue.
3. BI Publisher Cache Directory Filling Up and Pointing to Invalid Directory Instead of system-tmp-dir Parameter
Symptoms
Temporary and cache files are written to .../j2ee/home/applications/xmlpserver/xmlpserver/xdo/cache but not to the path configured in the file web.xml file:
<param-name>system-tmp-dir</param-name> <param-value>/servers/bipublisher/XMLP/Cache</param-value> So no matter where has been set the temp directory, it still writes to the cache location. As a result when a report is submitted the file system is filling up.
Cause
The cause of this problem has been identified in unpublishedBug 9560562: BI PUBLISHER CACHE DIRECTORY FILLING UP AND POINTING TO INVALID DIRECTORY.
Fix for unpublished Bug 9560562 has been included in Patch 9791839 : UPDATE FOR BI PUBLISHER ENTERPRISE 10.1.3.4.1 JUNE 2010.
With this fix, Administrator can define System Temporary Directory from Admin->Server Configuration and BIP uses this directory for caching
Solution
1. Please apply the Patch 9791839
2. Set the temporary directory in Admin->Server Configuration
3. Bounce the services .
4. Then test again.