ITPub博客

首页 > 数据库 > 数据库开发技术 > powerdesigner中name属性变为注释

powerdesigner中name属性变为注释

数据库开发技术 作者:drgfml 时间:2016-04-26 15:45:12 0 删除 编辑


原文出处:http://blog.sina.com.cn/s/blog_4cef5c7b01014lms.html

 在使用PowerDesigner对数据库进行概念模型和物理模型设计时,一般在NAME或Comment中写中文,在Code中写英文。Name用来显 示,Code在代码中使用,但Comment中的文字会保存到数据库Table或Column的Comment中,当Name已经存在的时候,再写一次 Comment很麻烦,可以使用以下代码来解决这个问题:
代码一:将Name中的字符COPY至Comment中

Option   Explicit   
ValidationMode   =   True   
InteractiveMode   =   im_Batch  
 
Dim   mdl   '   the   current   model  
 
'   get   the   current   active   model   
Set   mdl   =   ActiveModel   
If   (mdl   Is   Nothing)   Then   
        MsgBox   "There   is   no   current   Model "    
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then   
        MsgBox   "The   current   model   is   not   an   Physical   Data   model. "    
Else   
       ProcessFolder   mdl   
 End   If  
  
  '   This   routine   copy   name   into   comment   for   each   table,  each   column   and   each   view    
'   of   the   current   folder   
 Private   sub   ProcessFolder(folder)   
       Dim   Tab   'running     table   
        for   each   Tab   in   folder.tables    
             if   not   tab.isShortcut   then    
                  tab.comment   =   tab.name   
                   Dim   col   '   running   column   
                    for   each   col   in   tab.columns    
                        col.comment=   col.name   
                   next   
              end   if    
      next  
  
       Dim   view   'running   view   
        for   each   view   in   folder.Views    
             if   not   view.isShortcut   then    
                  view.comment   =   view.name   
              end   if    
      next  
  
       '   go   into   the   sub-packages   
       Dim   f   '   running   folder   
       For   Each   f   In   folder.Packages   
              if   not   f.IsShortcut   then    
                  ProcessFolder   f   
              end   if    
      Next   
 end   sub

注意:如果不想把以前写的注释给覆盖掉 ,那么把上面的红色标记处 改成: col.comment= col.name +col.comment 那么注释就是追加的了

另外在使用REVERSE ENGINEER从数据库反向生成PDM的时候,PDM中的表的NAME和CODE事实上都是CODE,为了把NAME替换为数据库中Table或Column的中文Comment,可以使用以下脚本:

代码二:将Comment中的字符COPY至Name中
Option   Explicit   
ValidationMode   =   True   
InteractiveMode   =   im_Batch  
 
Dim   mdl   '   the   current   model  
 
'   get   the   current   active   model   
Set   mdl   =   ActiveModel   
If   (mdl   Is   Nothing)   Then   
        MsgBox   "There   is   no   current   Model "    
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then   
        MsgBox   "The   current   model   is   not   an   Physical   Data   model. "    
Else   
       ProcessFolder   mdl   
 End   If  
  
 Private   sub   ProcessFolder(folder)   
 On Error Resume Next  
       Dim   Tab   'running     table   
        for   each   Tab   in   folder.tables    
             if   not   tab.isShortcut   then    
                  tab.name   =   tab.comment  
                   Dim   col   '   running   column   
                    for   each   col   in   tab.columns    
                   if col.comment="" then   
                   else  
                        col.name=   col.comment   
                    end if  
                  next   
              end   if    
      next  
  
       Dim   view   'running   view   
        for   each   view   in   folder.Views    
             if   not   view.isShortcut   then    
                  view.name   =   view.comment   
              end   if    
      next  
  
       '   go   into   the   sub-packages   
       Dim   f   '   running   folder   
       For   Each   f   In   folder.Packages   
              if   not   f.IsShortcut   then    
                  ProcessFolder   f   
              end   if    
      Next   
 end   sub

 

========================================================================================

为了让name的内容和comment的内容合并作为注释,可以使用如下脚本

'******************************************************************************
'* File: name2comment.vbs
'* Purpose: Database generation cannot use object names anymore
' in version 7 and above.
' It always uses the object codes.
'
' In case the object codes are not aligned with your
' object names in your model, this script will copy
' the object Name onto the object Comment for
' the Tables and Columns.
'
'* Title:
'* Version: 1.0
'* Company: Sybase Inc.
'******************************************************************************


Option Explicit
ValidationMode = True
InteractiveMode = im_Batch

Dim mdl ' the current model

' get the current active model
Set mdl = ActiveModel
If (mdl Is Nothing) Then
MsgBox "There is no current Model "
ElseIf Not mdl.IsKindOf(PdPDM.cls_Model) Then
MsgBox "The current model is not an Physical Data model. "
Else
ProcessFolder mdl
End If

' This routine copy name into comment for each table, each column and each view
' of the current folder
Private sub ProcessFolder(folder)
Dim Tab 'running table
for each Tab in folder.tables
if not tab.isShortcut then
'把表明作为表注释,其实不用这么做
tab.comment = tab.name
Dim col ' running column
for each col in tab.columns
'把列name和comment合并为comment
col.comment= col.name+col.comment
next
end if
next

Dim view 'running view
for each view in folder.Views
if not view.isShortcut then
view.comment = view.name
end if
next

' go into the sub-packages
Dim f ' running folder
For Each f In folder.Packages
if not f.IsShortcut then
ProcessFolder f
end if
Next
end sub

 


以上两段代码都是VB脚本,在PowerDesigner中使用方法为:
PowerDesigner->Tools->Execute Commands->Edit/Run Scripts
将代码Copy进去执行就可以了,是对整个CDM或PDM进行操作

来自 “ ITPUB博客 ” ,链接:https://blog.itpub.net/96210/viewspace-2088645/ ,如需转载,请注明出处,否则将追究法律责任。

请登录后发表评论 登录
全部评论
  • 博文量
    32
  • 访问量
    59161