MegaCLI Scripts

原创 Linux操作系统 作者:wzgchen 时间:2016-06-12 16:59:26 0 删除 编辑

Installing the MegaCLI binary

In order to communicate with the LSI card you will need the MegaCLI or MegaCLI64 (64bit) program. The install should be quite easy, but LSI make us jump through a few hoops. This is what we found:

  • Go to the LSI Downloads page: LSI Downloads
  • Search by keyword "megacli
  • Click on "Management Software and Tools"
  • Download the MegaCLI zip file. You will see the same file is for DOS, Windows, Linux and FreeBSD.
  • Unzip the file
  • In the Linux directory there is an RPM. If you are using Redhat you can install it. For Ubuntu got the next step.
  • For Ubuntu run "rpm2cpio MegaCli-*.rpm | cpio -idmv" to expand the directory structure. You may need to "apt-get install rpm2cpio" .
  • For FreeBSD unzip the file in the FreeBSD directory.

On our Ubuntu Linux 64bit and FreeBSD 64bit servers we simply copied MegaCli64 (64bit) to /usr/local/sbin/ . You can put the binary anywhere you want, but we choose /usr/local/sbin/ because it is in root's path. Make sure to secure the binary. Make the owner root and chmod the binary to 700 (chown root /usr/local/sbin/MegaCli64; chmod 700 /usr/local/sbin/MegaCli64). The install is now done. We would like to see LSI make a Ubuntu PPA or FreeBSD ports entry sometime in the future, but this setup was not too bad.

使用命令:
ln -s /opt/MegaRAID/MegaCli/MegaCli64 /usr/bin/MegaCli
命令使用:
#MegaCli  -LDInfo -Lall -aALL 查raid级别
#MegaCli -AdpAllInfo -aALL 查raid卡信息
#MegaCli -PDList -aALL 查看硬盘信息
#MegaCli -AdpBbuCmd -aAll 查看电池信息
#MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志
#MegaCli -adpCount 【显示适配器个数】
#MegaCli -AdpGetTime –aALL 【显示适配器时间】
#MegaCli -AdpAllInfo -aAll    【显示所有适配器信息】
#MegaCli -LDInfo -LALL -aAll    【显示所有逻辑磁盘组信息】
#MegaCli -PDList -aAll    【显示所有的物理信息】
#MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】
#MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】
#MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】
#MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL    【显示BBU设计参数】
#MegaCli -AdpBbuCmd -GetBbuProperties -aALL    【显示当前BBU属性】
#MegaCli -cfgdsply -aALL    【显示Raid卡型号,Raid设置,Disk相关信息】
3.磁带状态的变化,从拔盘,到插盘的过程中。
Device        |Normal|Damage|Rebuild|Normal
Virtual Drive    |Optimal|Degraded|Degraded|Optimal
Physical Drive    |Online|Failed –> Unconfigured|Rebuild|Online
4.查看磁盘缓存策略
#MegaCli -LDGetProp -Cache -L0 -a0
or
#MegaCli -LDGetProp -Cache -L1 -a0
or
#MegaCli -LDGetProp -Cache -LALL -a0
ro
#MegaCli -LDGetProp -Cache -LALL -aALL
ro
#MegaCli -LDGetProp -DskCache -LALL -aALL
5.设置磁盘缓存策略
缓存策略解释:
WT    (Write through
WB    (Write back)
NORA  (No read ahead)
RA    (Read ahead)
ADRA  (Adaptive read ahead)
Cached
Direct
例子:
#MegaCli -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0
or
#MegaCli -LDSetProp -Cached|-Direct -L0 -a0
or
enable / disable disk cache
#MegaCli -LDSetProp -EnDskCache|-DisDskCache -L0 -a0
6.创建一个 raid5 阵列,由物理盘 2,3,4 构成,该阵列的热备盘是物理盘 5
#MegaCli -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -Hsp[1:5] -a0
7.创建阵列,不指定热备
#MegaCli -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -a0
8.删除阵列
#MegaCli -CfgLdDel -L1 -a0
9.在线添加磁盘
#MegaCli -LDRecon -Start -r5 -Add -PhysDrv[1:4] -L1 -a0
10.阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。
#MegaCli -LDInit -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
#MegaCli -LDInit -ProgDsply -LALL -aALL
11.查看阵列后台初始化进度
#MegaCli -LDBI -ShowProg -LALL -aALL
或者以动态可视化文字界面显示
#MegaCli -LDBI -ProgDsply -LALL -aALL
12.指定第 5 块盘作为全局热备
#MegaCli -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0
13.指定为某个阵列的专用热备
#MegaCli -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0
14.删除全局热备
#MegaCli -PDHSP -Rmv -PhysDrv[1:5] -a0
15.将某块物理盘下线/上线
#MegaCli -PDOffline -PhysDrv [1:4] -a0
#MegaCli -PDOnline -PhysDrv [1:4] -a0
16.查看物理磁盘重建进度
#MegaCli -PDRbld -ShowProg -PhysDrv [1:5] -a0
或者以动态可视化文字界面显示
#MegaCli -PDRbld -ProgDsply -PhysDrv [1:5] -a0


查看RAID卡信息
megacli64 -AdpAllinfo -a0
product name:
memory size:
write policy:WB
read poliyc:none
cache when bbu bad:disabled
cached io:no

cache policy:writeback,readaheadnone,direct,no write cache if bad bbu
开启了writeback,关闭了raid卡的预读,写入为直接写入,当bbu有问题或充电时禁用writeback

How do I us

e the lsi.sh script ?

 ./lsi.sh status
 ./lsi.sh drives


./lsi.sh progress


The lsi.sh MegaCLI interface script


#!/bin/bash
#
# Calomel.org 
#     https://calomel.org/megacli_lsi_commands.html
#     LSI MegaRaid CLI 
#     lsi.sh @ Version 0.05
#
# description: MegaCLI script to configure and monitor LSI raid cards.

# Full path to the MegaRaid CLI binary
MegaCli="/usr/local/sbin/MegaCli64"

# The identifying number of the enclosure. Default for our systems is "8". Use
# "MegaCli64 -PDlist -a0 | grep "Enclosure Device"" to see what your number
# is and set this variable.
ENCLOSURE="8"

if [ $# -eq 0 ]
   then
    echo ""
    echo "            OBPG  .:.  lsi.sh $arg1 $arg2"
    echo "-----------------------------------------------------"
    echo "status        = Status of Virtual drives (volumes)"
    echo "drives        = Status of hard drives"
    echo "ident \$slot   = Blink light on drive (need slot number)"
    echo "good \$slot    = Simply makes the slot \"Unconfigured(good)\" (need slot number)"
    echo "replace \$slot = Replace \"Unconfigured(bad)\" drive (need slot number)"
    echo "progress      = Status of drive rebuild"
    echo "errors        = Show drive errors which are non-zero"
    echo "bat           = Battery health and capacity"
    echo "batrelearn    = Force BBU re-learn cycle"
    echo "logs          = Print card logs"
    echo "checkNemail   = Check volume(s) and send email on raid errors"
    echo "allinfo       = Print out all settings and information about the card"
    echo "settime       = Set the raid card's time to the current system time"
    echo "setdefaults   = Set preferred default settings for new raid setup"
    echo ""
   exit
 fi

# General status of all RAID virtual disks or volumes and if PATROL disk check
# is running.
if [ $1 = "status" ]
   then
      $MegaCli -LDInfo -Lall -aALL -NoLog
      echo "###############################################"
      $MegaCli -AdpPR -Info -aALL -NoLog
      echo "###############################################"
      $MegaCli -LDCC -ShowProg -LALL -aALL -NoLog
   exit
fi

# Shows the state of all drives and if they are online, unconfigured or missing.
if [ $1 = "drives" ]
   then
      $MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g'
   exit
fi

# Use to blink the light on the slot in question. Hit enter again to turn the blinking light off.
if [ $1 = "ident" ]
   then
      $MegaCli  -PdLocate -start -physdrv[$ENCLOSURE:$2] -a0 -NoLog
      logger "`hostname` - identifying enclosure $ENCLOSURE, drive $2 "
      read -p "Press [Enter] key to turn off light..."
      $MegaCli  -PdLocate -stop -physdrv[$ENCLOSURE:$2] -a0 -NoLog
   exit
fi

# When a new drive is inserted it might have old RAID headers on it. This
# method simply removes old RAID configs from the drive in the slot and make
# the drive "good." Basically, Unconfigured(bad) to Unconfigured(good). We use
# this method on our FreeBSD ZFS machines before the drive is added back into
# the zfs pool.
if [ $1 = "good" ]
   then
      # set Unconfigured(bad) to Unconfigured(good)
      $MegaCli -PDMakeGood -PhysDrv[$ENCLOSURE:$2] -a0 -NoLog
      # clear 'Foreign' flag or invalid raid header on replacement drive
      $MegaCli -CfgForeign -Clear -aALL -NoLog
   exit
fi

# Use to diagnose bad drives. When no errors are shown only the slot numbers
# will print out. If a drive(s) has an error you will see the number of errors
# under the slot number. At this point you can decided to replace the flaky
# drive. Bad drives might not fail right away and will slow down your raid with
# read/write retries or corrupt data. 
if [ $1 = "errors" ]
   then
      echo "Slot Number: 0"; $MegaCli -PDlist -aALL -NoLog | egrep -i 'error|fail|slot' | egrep -v ' 0'
   exit
fi

# status of the battery and the amount of charge. Without a working Battery
# Backup Unit (BBU) most of the LSI read/write caching will be disabled
# automatically. You want caching for speed so make sure the battery is ok.
if [ $1 = "bat" ]
   then
      $MegaCli -AdpBbuCmd -aAll -NoLog
   exit
fi

# Force a Battery Backup Unit (BBU) re-learn cycle. This will discharge the
# lithium BBU unit and recharge it. This check might take a few hours and you
# will want to always run this in off hours. LSI suggests a battery relearn
# monthly or so. We actually run it every three(3) months by way of a cron job.
# Understand if your "Current Cache Policy" is set to "No Write Cache if Bad
# BBU" then write-cache will be disabled during this check. This means writes
# to the raid will be VERY slow at about 1/10th normal speed. NOTE: if the
# battery is new (new bats should charge for a few hours before they register)
# or if the BBU comes up and says it has no charge try powering off the machine
# and restart it. This will force the LSI card to re-evaluate the BBU. Silly
# but it works.
if [ $1 = "batrelearn" ]
   then
      $MegaCli -AdpBbuCmd -BbuLearn -aALL -NoLog
   exit
fi

# Use to replace a drive. You need the slot number and may want to use the
# "drives" method to show which drive in a slot is "Unconfigured(bad)". Once
# the new drive is in the slot and spun up this method will bring the drive
# online, clear any foreign raid headers from the replacement drive and set the
# drive as a hot spare. We will also tell the card to start rebuilding if it
# does not start automatically. The raid should start rebuilding right away
# either way. NOTE: if you pass a slot number which is already part of the raid
# by mistake the LSI raid card is smart enough to just error out and _NOT_
# destroy the raid drive, thankfully.
if [ $1 = "replace" ]
   then
      logger "`hostname` - REPLACE enclosure $ENCLOSURE, drive $2 "
      # set Unconfigured(bad) to Unconfigured(good)
      $MegaCli -PDMakeGood -PhysDrv[$ENCLOSURE:$2] -a0 -NoLog
      # clear 'Foreign' flag or invalid raid header on replacement drive
      $MegaCli -CfgForeign -Clear -aALL -NoLog
      # set drive as hot spare
      $MegaCli -PDHSP -Set -PhysDrv [$ENCLOSURE:$2] -a0 -NoLog
      # show rebuild progress on replacement drive just to make sure it starts
      $MegaCli -PDRbld -ShowProg -PhysDrv [$ENCLOSURE:$2] -a0 -NoLog
   exit
fi

# Print all the logs from the LSI raid card. You can grep on the output.
if [ $1 = "logs" ]
   then
      $MegaCli -FwTermLog -Dsply -aALL -NoLog
   exit
fi

# Use to query the RAID card and find the drive which is rebuilding. The script
# will then query the rebuilding drive to see what percentage it is rebuilt and
# how much time it has taken so far. You can then guess-ti-mate the
# completion time.
if [ $1 = "progress" ]
   then
      DRIVE=`$MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g' | egrep build | awk '{print $3}'`
      $MegaCli -PDRbld -ShowProg -PhysDrv [$ENCLOSURE:$DRIVE] -a0 -NoLog
   exit
fi

# Use to check the status of the raid. If the raid is degraded or faulty the
# script will send email to the address in the $EMAIL variable. We normally add
# this method to a cron job to be run every few hours so we are notified of any
# issues.
if [ $1 = "checkNemail" ]
   then
      EMAIL="raidadmin@localhost"

      # Check if raid is in good condition
      STATUS=`$MegaCli -LDInfo -Lall -aALL -NoLog | egrep -i 'fail|degrad|error'`

      # On bad raid status send email with basic drive information
      if [ "$STATUS" ]; then
         $MegaCli -PDlist -aALL -NoLog | egrep 'Slot|state' | awk '/Slot/{if (x)print x;x="";}{x=(!x)?$0:x" -"$0;}END{print x;}' | sed 's/Firmware state://g' | mail -s `hostname`' - RAID Notification' $EMAIL
      fi
fi

# Use to print all information about the LSI raid card. Check default options,
# firmware version (FW Package Build), battery back-up unit presence, installed
# cache memory and the capabilities of the adapter. Pipe to grep to find the
# term you need.
if [ $1 = "allinfo" ]
   then
      $MegaCli -AdpAllInfo -aAll -NoLog
   exit
fi

# Update the LSI card's time with the current operating system time. You may
# want to setup a cron job to call this method once a day or whenever you
# think the raid card's time might drift too much. 
if [ $1 = "settime" ]
   then
      $MegaCli -AdpGetTime -aALL -NoLog
      $MegaCli -AdpSetTime `date +%Y%m%d` `date +%H:%M:%S` -aALL -NoLog
      $MegaCli -AdpGetTime -aALL -NoLog
   exit
fi

# These are the defaults we like to use on the hundreds of raids we manage. You
# will want to go through each option here and make sure you want to use them
# too. These options are for speed optimization, build rate tweaks and PATROL
# options. When setting up a new machine we simply execute the "setdefaults"
# method and the raid is configured. You can use this on live raids too.
if [ $1 = "setdefaults" ]
   then
      # Read Cache enabled specifies that all reads are buffered in cache memory. 
       $MegaCli -LDSetProp -Cached -LAll -aAll -NoLog
      # Adaptive Read-Ahead if the controller receives several requests to sequential sectors
       $MegaCli -LDSetProp ADRA -LALL -aALL -NoLog
      # Hard Disk cache policy enabled allowing the drive to use internal caching too
       $MegaCli -LDSetProp EnDskCache -LAll -aAll -NoLog
      # Write-Back cache enabled
       $MegaCli -LDSetProp WB -LALL -aALL -NoLog
      # Continue booting with data stuck in cache. Set Boot with Pinned Cache Enabled.
       $MegaCli -AdpSetProp -BootWithPinnedCache -1 -aALL -NoLog
      # PATROL run every 672 hours or monthly (RAID6 77TB @60% rebuild takes 21 hours)
       $MegaCli -AdpPR -SetDelay 672 -aALL -NoLog
      # Check Consistency every 672 hours or monthly
       $MegaCli -AdpCcSched -SetDelay 672 -aALL -NoLog
      # Enable autobuild when a new Unconfigured(good) drive is inserted or set to hot spare
       $MegaCli -AdpAutoRbld -Enbl -a0 -NoLog
      # RAID rebuild rate to 60% (build quick before another failure)
       $MegaCli -AdpSetProp \{RebuildRate -60\} -aALL -NoLog
      # RAID check consistency rate to 60% (fast parity checks)
       $MegaCli -AdpSetProp \{CCRate -60\} -aALL -NoLog
      # Enable Native Command Queue (NCQ) on all drives
       $MegaCli -AdpSetProp NCQEnbl -aAll -NoLog
      # Sound alarm disabled (server room is too loud anyways)
       $MegaCli -AdpSetProp AlarmDsbl -aALL -NoLog
      # Use write-back cache mode even if BBU is bad. Make sure your machine is on UPS too.
       $MegaCli -LDSetProp CachedBadBBU -LAll -aAll -NoLog
      # Disable auto learn BBU check which can severely affect raid speeds
       OUTBBU=$(mktemp /tmp/output.XXXXXXXXXX)
       echo "autoLearnMode=1" > $OUTBBU
       $MegaCli -AdpBbuCmd -SetBbuProperties -f $OUTBBU -a0 -NoLog
       rm -rf $OUTBBU
   exit
fi

### EOF ###
 


                                                    