原创 Linux操作系统 作者:leodinas_kong 时间:2017-09-22 09:06:22 0 删除 编辑

# swcopy -x enforce_dependencies=FALSE -s /tmp/hp/hp20161201/driver/HP_UX_11.31_10GigEthr-05_B.11.31.1608_HP-UX_B.11.31_IA.depot         * @ /tmp/hp/hp20161201/driver/driver

 

=======  11/28/16 10:45:34 EAT  BEGIN swcopy SESSION (non-interactive)
         (jobid=lmsif01-0241)

       * Session started for user "root@lmsif01".

       * Beginning Selection
       * "lmsif01:/tmp/hp/hp20161201/driver/driver":  This target does
         not exist and will be created.
NOTE:    The software "IOCXGBE-DRV" was successfully marked, but it
         depends on the following software items which could not be
         found in the source. However, these items may already be in
         the target. This will be checked during the Analysis Phase:
         Streams.STREAMS2-KRN,r>=B.11.31.%
         Networking.NETTL-RUN,r>=B.11.31.%
       * Source:
         /tmp/hp/hp20161201/driver/HP_UX_11.31_10GigEthr-03_B.11.31.1609_HP-UX_B.11.31_IA.depot

       * Targets:
         lmsif01:/tmp/hp/hp20161201/driver/driver
       * Software selections:
             10GigEthr-03,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP
             IOCXGBE-DRV.IOCXGBE-KRN,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGBE-RUN,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-FRE-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-FRE-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-GER-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-GER-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-ITA-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-ITA-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-JPN-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-JPN-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-KOR-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-KOR-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-SCH-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-SCH-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-SPA-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-SPA-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-TCH-U-HLP,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
             IOCXGBE-DRV.IOCXGE-TCH-U-MSG,r=B.11.31.1609,a=HP-UX_B.11.31_IA,v=HP,fr=B.11.31.1609,fa=HP-UX_B.11.31_IA
       * Selection succeeded.


       * Beginning Analysis and Execution
       * Session selections have been saved in the file
         "/.sw/sessions/swcopy.last".
WARNING: "lmsif01:/tmp/hp/hp20161201/driver/driver":  The software
         dependencies for 18 products or filesets cannot be resolved.
ERROR:   "lmsif01:/tmp/hp/hp20161201/driver/driver":  An update to the
         installed product database or depot catalog may have errors.
       * The execution phase failed for
         "lmsif01:/tmp/hp/hp20161201/driver/driver".
       * Analysis and Execution had errors.


ERROR:   More information may be found in the agent logfile using the
         command "swjob -a log lmsif01-0241 @
         lmsif01:/tmp/hp/hp20161201/driver/driver".

=======  11/28/16 10:46:10 EAT  END swcopy SESSION (non-interactive)
         (jobid=lmsif01-0241)


检查/tmp/hp/hp20161201/driver/driver/ 中生成的swagent.log 文件

解决: 800建议重启swagentd进程

# cd /sbin/init.d

# ./swagentd stop

# ./swagentd start

来自 “ ITPUB博客 ” ,链接:https://blog.itpub.net/31401608/viewspace-2145315/ ,如需转载,请注明出处,否则将追究法律责任。