首页 > 数据库 > 数据库开发技术 > PCSF_46007 No gateway connectivity is provided for domain. ERROR:

PCSF_46007 No gateway connectivity is provided for domain. ERROR:

翻译 数据库开发技术 作者:saintlu 时间:2016-06-29 11:30:31 0 删除 编辑
命令行下运行Informatica workflow报错PCSF_46007 No gateway connectivity is provided for domain. ERROR: Cannot connect to Integration Service
运行workflow命令:

点击(此处)折叠或打开

  1. pmcmd startworkflow -sv IS_PROD(集成服务) -d Domain_INFA(域) -u username -p password -f GLOBAL(文件夹) -wait worfflowname

解决办法:
windows下添加环境变量INFA_DOMAINS_FILE,值C:\Informatica\PowerCenter8.1.0\domains.infa

Windows:

  1. Right click My Computer.

  2. Click Properties.

  3. Select the Advanced Tab

  4. Click Environmental Variables...

  5. Click New... under System variables.

  6. Enter the following:

    • Variable Name: INFA_DOMAINS_FILE
    • Value Name: C:\Informatica\PowerCenter8.1.0\domains.infa.
    Note

    The domain.infa filename must be included in the path as show above.

  7. Click OK three times.

UNIX:

In a UNIX C shell environment, type the following:

setenv INFA_DOMAINS_FILE /domains.infa

In a UNIX Bourne shell environment, type the following:

INFA_DOMAINS_FILE=/domains.infa
export INFA_DOMAINS_FILE