ITPub博客

首页 > Linux操作系统 > Linux操作系统 > MRP:Workbench启用上Pegging功能,一点击页面就死掉解决方法

MRP:Workbench启用上Pegging功能,一点击页面就死掉解决方法

原创 Linux操作系统 作者:jarli 时间:2019-05-19 18:09:06 0 删除 编辑
1.应用:
MRP工作台启用上Pegging功能,一点击页面就死掉,
通过查询metalink,需要让DBA
Re-Generate JAR files using adadmin utility,就OK了。
2.相关文件:

Applies to:

Materials Requirement Planning - Version: 12.0.6
This problem can occur on any platform.

Symptoms

On 12.0.6 in Production:
In MRP workbench, the Pegging navigate object does not open and it Hangs.

EXPECTED BEHAVIOR.
-----------------------------
Expect pegging form. opens up...

STEPS TO REPRODUCE
-------------------------------

1. Navigate to MRP Workbench.

2. Select a Planned Order and click on Pegging.

3. The form. hangs and does not open up the Pegging window.

Cause

This problem usually occurs when doing Fresh Installations/Upgrading/Cloning.As some Post
Install/Upgrade/Clone steps were incomplete.

This issue is described in Metalink Note & TAR...

Note 785165.1 : .

Solution

To implement the solution, please execute the following steps:

1. Re-Generate JAR files using adadmin utility

2. Retest the issue.

3. Migrate the solution as appropriate to other environments.